BTS-20V10A Battery tester |
Model Number: | BTS- | 20 | V | 10 | A | Battery tester | Material code: | CT-3008 | -20V10A | – | NA | – | P |
items | Parameter |
Input power | AC 220V ±10% / 60Hz |
Input active power | 2228 | W |
resolution ratio | AD:16bit;DA:12bit |
Input impedance | ≥1MΩ |
voltage | Constant voltage range | 100mV~20V | |
Minimum discharge voltage | 2.5V |
accuracy | ± 0.1% of FS |
stability | ± 0.1% of FS |
current | Output range/channel | 50mA~10A |
accuracy | ± 0.1% of FS |
Constant voltage cut-off current | 0.02A |
stability | ± 0.1% of FS |
power | Output range/channel | 200W |
stability | ± 0.2% of FS |
time | Current response time | maximum current rising time:20ms |
working step time range | ≤(365*24)h/working step | Time format00:00:00(h,min,s) |
Data record | Record data conditions | Minimum sampling time:1s |
Minimum sampling voltage:40mV |
Minimum sampling current:20mA |
Record frequency | 1Hz |
Charge | Charge mode | constant-current charge,constant-voltage charge,constant voltage and current charge |
cut-off conditions | Voltage,current,relative time,capacity,-△V |
discharge | Discharge mode | constant current discharge, constant watt discharge |
cut-off conditions | Voltage,current,relative time,capacity,-△V |
cycle | Loop test range | 1~65535 times |
Single cycle working steps | 254 |
Loop nest | Nested loop function,max 3 layers |
Protection | ● Data Protection |
● off-line test |
● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time |
●anti reverse connection |
IP Protection Class | IP20 |
Channel feature | constant current and voltage source ;double closed-loop; |
Channel control mode | independent |
Current/voltage detection sampling | four-wire connection |
noise | <85dB |
data base | MySQL centralized management of test datas |
upper computer communication mode | TCP/IP |
Data output mode | EXCEL2003,2010,TXT |
Server disk Configuration | 500GB |
Server operating system | Windows 7 |
communication interface | ethernet |
Working environment requirement |
item | parameter |
working temp. range | 0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) |
Storage temp. range | -10℃~50℃ |
Working environment relative humidity range | ≤70% RH(no water vapor condensation) |
Storage environment relative humidity range | ≤80% RH(no water vapor condensation) |
Clamp specification and size |
item | parameter |
Clamp type | Polymer clamp |
Alligator clamp | Polymer clamp | cable feet clamp |
Pictures are for reference only,real objects shall prevail.Choose one |
Cabinet size/unit(W*D*H)(mm) | 12U(19”),600*600*740 |
Equipment pic | |
Pictures are for reference only,real objects shall prevail. |