Formaldehyde and VOC Tester

Formaldehyde Release Capsule

Usage: 

*confirm the influence of environment variables on the release rate and release properties of materials and products;

*Grade materials and products according to their release properties;

*Develop and validate the proposed model of indoor air pollutions;  

*Evaluate indoor air quality(IAQ) according to the data and proposed model of indoor pollutants; 

 

Reference Standards:     

*GB 18580 ”Indoor Decorating and Renovating Materials Limit of Formaldehyde Emission of Manmade Board and its Products” 

*GB 18587  ”Indoor Decorating and Renovating Materials Releasing Limitation of Harmful Substances from Carpet,Carpet Pad and Carpet Adhesive”    

*GB 18584  ”Indoor Decorating and Renovating Materials Limits of Harmful Substances from Wooden Furniture(Exposure draft)    

*Upholstered Furniture Limits of Harmful Substances from Sofa(Exposure draft) and Climate Chamber for Detection of Volatile Organic Compounds in Furniture(Exposure draft)         

*LY/T1980-2011 “Detection Box for Release Quantity of Volatile Organic Compounds(VOC) and Formaldehyde LY/T 1981-2011 Detection Box for Release Quantity of Formaldehyde with Gas Analysis Method” 

*LY/T1982-2011 “Large Climate Chamber for Detection of Release Quantity of  Formaldehyde of Manmade Board and its Products” 

 

 

Technical Parameters:

 

Product Model

C-50

C-100

C-250

C-500

C-1000

Volume of chamber(WxDxH)

56*30*30

63*40*40

70*60*60

102*70*70

158*80*80

Environmental temperature

5~35℃

Environmental humidity

≤90%R.H

Requirements for Environmental

Cleanliness No pollutant source in the surrounding environment TVOC 500μg/m³

Adjustable range of  temperature

10~40℃ high temperature cleaning 250℃

Adjustable range of  humidity

40~70%R.H(20℃~30℃)

Pressure

10±5pa

Temperature fluctuation

±0.3℃(fluctuation)

Temperature deviation

±0.5℃(deviation)

Humidity fluctuation

±2.5%R.H

Humidity  deviation

±3%

Air exchange rate

0.2~5/h±5%(optional  0.2~3/h±5%)

Air velocity

0.1m/s  0.3m/s(Range)

Power

Alternating current 380V/50Hz three-phase power supply 4/5 wiring system

Starting power

11kw

18kw

30kw

35kw

Operating power

5kw

8kw

14kw

16kw

Rate of recovery

Formaldehyde have a recovery rate larger than 90%

Clean air system

Standard configuration

Background concentration for formaldehyde

smaller than 15μg/m³,the lowest 6μg/m³