Cable Control Equipment

HF Spartk Tester abet 5015E

Description :

   abet5015E High Frequency spark tester is a efficient and  reliable product inspection tool, a precision instrument to detect various types of wire and cable the conductor insulation layer of pinhole, broken skin, bare copper and so on poor insulation points. It can quickly detect the layer defect without damaging the inner electrical conductor.  Use high frequency (3KHz) high volt elctrode replace traditional (50/60Hz) high volt electrode, its electrode tip can select a 50/120mm beaded -contact , copper brush , carbon  brush, or a roller , greatly smaller installation dimensions , greatly improved detection speed ( 1200-2400m/min ). This high frequency spark tester is a reliability high quality control tool.

Fuctions:

1.this tester return detecting 0.1s after conductor fault detected.

2.electrode tip size is 50 times smaller than traditional electrode tip(50Hz).

3.test voltage adjustable from 0 to 15K VR.M.S.

4.the instant sparks will not destroy the good insulation of wire comductor.

5.limited fault current, will not damage the test equipment.

6.rapid detect pinhole and nonintact wire conductor fault.

7.Closing lines or host failure or start -linked signal control .

8.with safety switch interlock protection device.

 

 

1.comply with the requirements of GB/3048.9-94. JB472810、VD0281、EN50356、BS5099、CCC and so on standards. Detection sensitivity <600UA.

2.Meet the requiremetns of UL1581-1990.

3.this instrument adopt oil-immersed or epoxy resin casting ignition coil, product can be detected with water, and a self-test device can detect weather the instrument is working properly(breakdown, counting, sound and light alarm)
note: UL or new GB standards instrument please special statement.(special specifications can be made to order)

 

HF spark tester specifications:

test voltage:AC 0.5-15KV    AC pluse factor:les than 5%  Short-circuit current:3-4mA                           

Breakdown sensetivity:I=600±50uA,t≤0.005s   Effective detection voltage:AC0.1-10KV

Sensitivity range:200-2000uA  Power supply:AC220V ±15%    Electrode:50/120mm

Max breakdown count frequency:10 times per second     Max test speed:1200/2400m/min 

Voltage stability:power input ±15%, output be constant 

Max cable diameter:ø5mm(10-200 to be custom made)

Output frequency:2.5~3.5KHz                    Output control:relay output 5A/250V                       

High volt test electrode tip: Bead/copper brush/carbon brush/roller

Weight:controller displayer  7KG ,high volt test head  9KG.

Working environment:

Power supply:  AC220V±15%      Power frequency:  50±2Hz        Input power:  120VA                                        

Temperature:  -10~45℃   Humidity: >85%(no condensed water)    Working mode:continuous

Breakdown indication:

Auto mode:instrument back to detection automatically after alarm.

Manual mode:instrument bact to detection only when worker press the reset button after alarm.

Safety Interlock: high volt will be cut off when open the cover, meanwhile spray piont grounded to ensure worker’s safety. also, it can control the high volt on/off of external control circuit(say stop take-up, cut off high volt, spark fault, cable stop collecting)